Model: GL-B133B-EC-M3
Rated voltage: 230 VAC, 50/60 Hz
Rated speed: 3800±5% RPM
Maximum input power: 30 W; maximum input current: 0.23 A

MOQ:100 pcs· Standard lead time:15-25 days· Engineering sample.7-10 datys

Description
Technical Parameters

Suzhou Blauberg Motoren Technology Co., Ltd. is one of the leading manufacturers and suppliers of blauberg gl-b133b-ec-m3 133mm ec backward curved centrifugal fan in China. Welcome to buy bulk high quality customized products made in China here and get quotation from our factory. For price consultation, contact us.

 

The Blauberg GL-B133B-EC-M3 is a 230 VAC EC backward curved centrifugal fan with 0-10 VDC/PWM speed control. It provides a nominal speed of 3800卤5% RPM at free-air conditions, with integrated protection functions and a ball-bearing motor.

Basic Info
Model GL-B133B-EC-M3 Product Type EC Backward Curved Centrifugal Fan
Motor EC059AC230V040W Phase 1~
Nominal Voltage 230 VAC Voltage Range 184-276 VAC
Frequency 50/60 Hz Data Condition FA (Free Air)
Nominal Speed 3800±5% RPM Max. Input Power 30 W
Max. Input Current 0.23 A Sound Level 63 dB(A)
Ambient Temperature -25℃ to +60℃ Release Date 7 August 2025

ML = Max. load; ME = Max. efficiency; FA = Free Air.

Technical Description
Fan Size (L*W*H) 165*165*85 mm Weight Not specified
Motor Size 59 Impeller Material Plastic
Number of Blades 7 Rotation Clockwise, viewed toward rotor
Degree of Protection IP55 Insulation Class Class B
Operating Mode S1 Bearing Ball bearing
Transport / Storage Temperature -40℃ to +80℃ Operating Humidity 5%-90% RH
Installation Position Any Cable Length 500±20 mm
Control Input 0-10 VDC / PWM, max. PWM input 10 VDC Voltage Output 10 VDC, max. 10 mA
Protection Functions Locked-rotor, thermal, overvoltage, undervoltage and overcurrent protection; soft start
Conformity CCC, CE, RoHS Dielectric Strength 1800 VAC / 50 Hz, 1 s; leakage current ≤10 mA
Product Application
1 Charging Column 9 Equipment Cooling Project
2 Kitchen Smoke Exhaust System 10 Ventilation Unit Project
3 FFU Project 11 AHU Project
4 Computer Room Cooling 12 Air Purifier Project
5 Rail Transit Air-Conditioning 13 Heat Exchanger Project
6 Electrical Appliances 14 Telecom Container Project
7 FanGrid Project 15 Data Center Cooling Project
8 Ventilation Equipment Project 16 Industrial Cooling System
Air Performance

air-performance

Air performance is measured according to AMCA 210 / GB 1236 installation category A. The values are valid under the specified measuring conditions and may vary with installation conditions. For deviations from the standard configuration, verify the parameters on the installed unit.

Overal Dimmensions

overall-dimensions

1 AC Cable PVC 3XAWG20
2 DC Cable PVC 4XAWG24
Electrical Connection

electrical-connection

Line Connection Designation Colour Function / Assignment
Power Line PE PE Green / Yellow Protective earth
Power Line U1 L Brown Power supply, live wire
Power Line U2 N Blue Power supply, neutral wire
Control Line U4 +10V Red Fixed 10 VDC output, max. 10 mA
Control Line U5 Speed Control Yellow 0-10 V / PWM control input
Control Line U6 Signal Feedback White Tach output, 2 pulses per revolution
Control Line U7 GND Blue Reference ground for control interface

Speed setting supports full-speed operation, 0-10 VDC voltage control, PWM control (1-10 kHz) and a 10 kw potentiometer. The tach output provides two pulses per revolution.

Note

Connect the power and control lines strictly according to the wiring diagram.

Do not connect the white signal wire directly to the red signal wire or an external DC power supply.

If the fan does not start, check the speed-control input voltage; do not touch the impeller or rotor after power is applied.

The fan takes several seconds to start; do not touch the impeller or rotor while energized or at low speed.

Before power-on, confirm that the motor is installed securely.

Do not pull the power cord; a damaged cord must be replaced by the manufacturer.

Do not drop or impact the motor.

Do not flush the motor.

Consult Blauberg before using customized products outside the agreed operating conditions.

The motor casing may remain hot after operation; take precautions against burns.

Keep debris out of the casing during installation.

Before installation and operation, turn the rotor by hand to confirm there is no collision, interference or jamming.

The motor must not be used without an impeller or load.

Store repackaged units in a clean, ventilated warehouse at -40℃ to +80℃, relative humidity no more than 95%, without corrosive gas and at least 15 cm above the ground.

Install the fan out of children's reach.

The final interpretation of this specification belongs to Blauberg.

Life and maintenance, warranty

The design life is 50,000 hours, limited by ball-bearing life at 40℃; actual service life varies with temperature, humidity, installation, load and other operating conditions.

Clean and maintain the fan every 3-6 months as appropriate for the environment.

The complete unit carries a two-year warranty from the delivery date for failures caused by product quality; damage caused by improper disassembly, handling, man-made damage, natural disasters or force majeure is excluded.

Download

GL-B133B-EC-M3 Product Specification N.pdf

 

Hot Tags: blauberg gl-b133b-ec-m3 133mm ec backward curved centrifugal fan, China blauberg gl-b133b-ec-m3 133mm ec backward curved centrifugal fan manufacturers, suppliers, factory

Send Inquiry
Get in touch
Let's engineer your air solution.

Complete the form and our engineering team will contact you shortly.

bg