Suzhou Blauberg Motoren Technology Co., Ltd. is one of the leading manufacturers and suppliers of high quality multi-purpose backward centrifugal radial fan adequate inventory in China. Welcome to buy bulk high quality customized products made in China here and get quotation from our factory. For price consultation, contact us.
Technical Parameters
Technical Description
Product Drawing
Dimensions in: mm

Performance Curve (P–Q)

Measuring requirements: Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection. Intake-side sound level: LwA according to 13347, L, A measured at 1 m distance from fan axis. The values given are only applicable under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked in installed condition.
Wiring Diagram
Click to view details
Click to collapse
| Conn. | Designation | Function / Assignment |
|---|---|---|
| P1 | PE | Protective Earth |
| L1 | Power supply, live wire see nameplate for voltage range | |
| L2 | Power supply, live wire see nameplate for voltage range | |
| L3 | Power supply, live wire see nameplate for voltage range | |
| P2 | NO | Status relay, Floating Status Contact |
| COM | Status relay, Point B, common connection, contact rating 250VAC/2A, isolated from power and control interfaces |
|
| NC | Normally Closed Switch,Circuit Breaker | |
| P3 | FG | Tach output, 5 pulse per revolution, (pulses can be customized, or changed to RD signal); SELV |
| GND | Reference ground for control interface; SELV | |
| Din1 | Connection of Digital input 1 enabling of electronics enabling of electronics; Opening pin or applied voltage 5-50V DC; Disabling bridge to GND or applied voltage < 1 V DC; |
|
| +10V | AnFixed voltage output 10 VDC ±5%, Imax.10mA, power supply for external devices (e.g. potentiometers); SELV | |
| +20V | AnFixed voltage output 20 VDC ±5%, Imax.10mA, power supply for external devices (e.g. potentiometers); SELV | |
| 4~20mA | Analogue Control input 4~20mA | |
| Ain1 U | 0-10V/PWM (Max. amplitude of PWM 10V) control input; SELV | |
| GND | Reference ground for control interface; SELV | |
| RSB | RS485 interface for MODBUS RSB; SELV | |
| RSA | RS485 interface for MODBUS RSA; SELV | |
| RSB | RS485 interface for MODBUS RSB; SELV | |
| RSA | RS485 interface for MODBUS RSA; SELV |
Speed Setting
Click to view details
Click to collapse

Fan will run full speed

Voltage higher than 1.0V DC, fan start up
Voltage lower than 0.5V DC, fan stop
≥1.0VDC Fan start up

PWM suggest amplitude: 10VDC (±5%)
PWM Frequency: 1KHz ~ 10KHz
PWM duty higher then 10%, fan start up
PWM duty lower then 5%, fan stop
≥10% PWM duty, fan start up

Voltage higher than 1.0V DC, fan start up
Voltage lower than 0.5V DC, fan stop
≥1.0VDC Fan start up

≥20mA n=MAX
4.5mA n=min
≤3.2mA n=0
Warranty & Note
Click to view details
Click to collapse
〉The power line and control line of the fan should be connected in strict accordance with the wiring diagram to prevent the fan from burning out.
〉Do not connect the white signal wire directly to the red signal wire or the external DC power supply.
〉If the fan does not work after starting, please check the input voltage of the speed regulation, which may be improperly connected. To prevent hand or other personal injury caused by sudden start of the fan, do not touch the impeller or rotor after electrifying.
〉It takes a few seconds for the fan to start after power on. In order to prevent personal injury, do not touch the impeller or rotor under the condition of electrifying or low-speed operating.
〉Before turning on the power, please check whether the motor is installed reliably, otherwise it will cause the motor to burn and personal accidents.
〉It is forbidden to pull the power cord too hard. If the power cord is damaged, it must be replaced by the manufacturer to avoid electric shock accidents.
〉It is forbidden to drop or crash the motor.
〉It is strictly forbidden to flush the motor, to prevent leakage accidents caused by reducing the insulation performance of the motor and endangering personal safety.
〉If you need to use special customized products for purposes other than the agreed working conditions, please consult our company first and confirm before use.
〉After the fan operation stops, the temperature of the motor casing may be high for a short period of time. Please avoid direct contact and take protective measures if necessary to prevent burns.
〉When installing the equipment, check the casing and other shells so that no debris can fall in, and clean up the inside if necessary.
〉Before the equipment is installed and running, the rotor should be pulled by hand to confirm that there is no collision, interference or jamming before it can be powered on.
〉As a part of the fan, the motor cannot be used alone without impeller or load.
〉After the product packaging has been disassembled, it should be repackaged if it needs to be kept in storage. The product shall be stored in a clean, well-ventilated warehouse with ambient temperature of -40℃~+80℃, relative humidity of no more than 95%, no corrosive gases in the air, and 15cm above the ground.
〉Please install the fan out of the reach of children and do not allow children to use this product.
〉The final interpretation right of this specification belongs to Blauberg.
Life and Maintenance
Click to view details
Click to collapse
Technical Support
Download product documentation - datasheets, certificates, wiring diagrams and manuals. Open online or save to your device.
![]()
Product Specification
![]()
Electrical connection diagram
![]()
CE Declaration of Conformity
![]()
Catalog card
![]()
User Manual
![]()
Performance data (P-Q)
Accessories
| Model | Type | Description | |
|---|---|---|---|
![]() |
VREB 2.5H | Speed controller | Single-phase, continuously variable thyristor speed governor in surface-mounted version. Designed for cooperation with single-phase (230 V / 50 Hz) motors, adapted for voltage speed control. |
![]() |
RS 1F-2B SP 16A LGO | Service switch | Lockable on-site service isolator switch for safe maintenance and disconnection of the fan. |
![]() |
AKU-COMP 250/1.2 | Silencer | A noise suppressor for flexible connections in ventilation ducts. |
![]() |
IRIS 250 | Ventilation damper | Complete range of dampers enabling measurement and regulation of air volume in a circular duct system. |
![]() |
ACOP PL 250 | Flexible connector | Anti-vibration connectors for fans with circular connection. |
![]() |
DF-K 250 | Filter | The complete filter is used to filter the air supply. Separation of larger pollutant particles prolongs the service life of devices placed behind the filter - fans, heaters, etc. |
See the fan in action
Watch how the EC backward-curved impeller delivers high airflow at low noise across the full speed range.
Questions and Answers (22)
Click to view details
Click to collapse
Q:What voltage range does this EC centrifugal fan support?
A:It runs on a wide input of 176–242 VAC (nominal 230 VAC) at 50/60 Hz.
By Blauberg Support on Mar 12, 2025
Q:Can I control the fan speed with a 0-10V signal?
A:Yes. The fan accepts 0-10V, PWM and RS485 (MODBUS) control inputs.
By David M. on Feb 28, 2025
Q:What is the maximum air flow of this model?
A:Max air flow is 3332 m³/h (1960 CFM) with ±10% tolerance.
By HVAC_Pro on Jan 19, 2025
Q:Is the motor suitable for continuous operation?
A:Yes, it is rated for S1 continuous duty with a 50,000-hour design life.
By Blauberg Support on Jan 05, 2025
Q:What is the protection rating (IP) of the fan?
A:The standard housing is rated IP44; an IP55 version is available on request.
By Sarah L. on Dec 22, 2024
Q:Which impeller material is used?
A:The impeller is aluminium alloy; the inlet plate and nozzle are galvanised sheet steel.
By Engineer_K on Dec 10, 2024
Q:Does the fan provide a tach / speed output signal?
A:Yes, the FG output gives 5 pulses per revolution (customisable, or an RD signal).
By Blauberg Support on Nov 30, 2024
Q:What is the noise level at maximum speed?
A:Sound power is 75 ±4 dB(A), measured per ISO 13347 at 1 m from the fan axis.
By Michael on Nov 12, 2024
Q:Can this fan be used in a FlowGrid / fan array?
A:Yes, the mounting holes are prepared for FlowGrid array installation.
By Blauberg Support on Oct 28, 2024
Q:What operating temperature range is allowed?
A:Ambient −25 ℃ to +60 ℃; occasional cold start down to −40 ℃ is permitted.
By Anna on Oct 15, 2024
Q:Do you offer OEM / customised versions?
A:Yes, we provide OEM/ODM customisation. Please contact our sales team with your requirements.
By Blauberg Support on Sep 30, 2024
Q:What certifications does the fan carry?
A:It conforms to EN 61800-5-1 and carries CE; approvals include UL, EAC and CSA.
By QA_Team on Sep 18, 2024
Q:Is reverse-polarity protection included?
A:Yes, the electronics include reverse-polarity, locked-rotor and over/under-voltage protection.
By Blauberg Support on Sep 02, 2024
Q:What is the warranty period?
A:The whole machine carries a two-year warranty from the delivery date.
By David M. on Aug 20, 2024
Q:How often should the fan be cleaned and maintained?
A:Depending on the environment, cleaning and maintenance every 3–6 months is recommended.
By Blauberg Support on Aug 05, 2024
Q:Can I use a 10K potentiometer to set the speed?
A:Yes, a 10K potentiometer is recommended; ≥1.0 VDC starts the fan, <0.5 VDC stops it.
By Tom on Jul 22, 2024
Q:What cable gland does the terminal box use?
A:An M20×1.5 gland for 4–10 mm cable, tightened to 4 ±0.6 Nm.
By Engineer_K on Jul 08, 2024
Q:What power input does it draw at full speed?
A:Rated power input is 594 W ±10% at 2.58 A.
By Blauberg Support on Jun 25, 2024
Q:Is a 4-20mA current control input supported?
A:Yes, 4–20 mA regulates speed: ≥20 mA = MAX, 4.5 mA = min, ≤3.2 mA = 0.
By HVAC_Pro on Jun 10, 2024
Q:What is the maximum static pressure?
A:Maximum static pressure is 740 Pa.
By Sarah L. on May 28, 2024
Q:Can the fan be mounted in any orientation?
A:Shaft horizontal or rotor on bottom; rotor-on-top is available on request.
By Blauberg Support on May 14, 2024
Q:What is the lead time for bulk orders?
A:Typical lead time is 15–25 days depending on quantity and customisation.