Blauberg SK-F225E-EC-05 225mm EC Single Inlet Centrifugal Blower

Blauberg SK-F225E-EC-05 225mm EC Single Inlet Centrifugal Blower

SK-F225E-EC-05 EC forward curved single inlet centrifugal blower with 230 VAC three-phase power, 0-10 V/PWM speed control, RS485 MODBUS-RTU, and IP55 protection.
Send Inquiry

MOQ:100 pcs· Standard lead time:15-25 days· Engineering sample.7-10 datys

Description
Technical Parameters

Suzhou Blauberg Motoren Technology Co., Ltd. is one of the leading manufacturers and suppliers of Blauberg SK-F225E-EC-05 225mm EC Single Inlet Centrifugal Blower in China. Welcome to buy bulk high quality customized products made in China here and get quotation from our factory. For price consultation, contact us.

 

Basic Info

Model SK-F225E-EC-05
Product Type EC Forward Curved Single Inlet Centrifugal Blower
Phase Three phase
Nominal Voltage 230 VAC
Control 0-10 VDC / PWM and RS485 MODBUS-RTU

Rated Data

Nominal Voltage Range 184-276 VAC
Frequency 50/60 Hz
Nominal Speed 2660 ±5% RPM
Max. Input Power 600 W
Max. Input Current 2.0 A
Sound Level 78 dB(A)
Ambient Temperature -25°C to +60°C

Technical Description

Fan Size (L × W × H) 370 × 318 × 196 mm
Motor Size 102
Impeller Material Galvanized sheet
Air Flow Direction All around; straight forward from air outlet
Rotation Direction Clockwise, viewed toward rotor
Rotor Surface Blue powder coating
Protection Degree IP55
Insulation Class Class F
Transport / Storage Temperature -40°C to +80°C
Operating Humidity 5%-90% RH
Storage Humidity 5%-95% RH
Installation Position Any
Operating Mode S1
Motor Bearing Ball bearing
Technical Features 10 VDC output; 0-10 VDC/PWM input; PFC; RS485 MODBUS-RTU; locked-rotor, thermal, over/under-voltage and overcurrent protection; soft start
Cable Length Standard 500 ±20 mm
Conformity CCC, CE, RoHS

Product Application

1.Charging Column 2.Kitchen Smoke Exhaust System
3.FFU Project 4.Computer Room Cooling
5.Rail Transit Air-Conditioning 6.Electrical Appliances
7.FanGrid Project 8.Ventilation Equipment Project
9.Equipment Cooling Project 10.Ventilation Unit Project
11.AHU Project 12Air Purifier Project
13.Heat Exchanger Project 14.Telecom Container Project
15.Data Center Cooling Project 16.Industrial Cooling System

Air Performance

product-1-1

Overall Dimensions

product-1-1

Electrical Connection

product-1-1

PE Protective earth - green/yellow
U0 / L1 Phase L1 - brown
U1 / L2 Phase L2 - blue
U2 / L3 Phase L3 - black
U3 / NC Status relay normally closed - white
U4 / COM Status relay common - gray
U5 / RSA RS485 MODBUS RSA - brown
U6 / RSB RS485 MODBUS RSB - gray
U7 / 0-10V PWM Speed-control input - yellow
U8 / FG Tach output, 5 pulses/revolution - white
U9 / +10V 10 VDC output - red
U10 / GND Control reference ground - blue

Note

  1. Connect the power and control wires strictly according to the wiring diagram to prevent damage.
  2. Do not connect the white signal wire directly to the red signal wire or an external DC power supply.
  3. If the fan does not operate after startup, check the speed-control input voltage and wiring.
  4. The fan takes several seconds to start; do not touch the impeller or rotor while energized or running at low speed.
  5. Before energizing, verify that the motor is installed securely.
  6. Do not pull the power cable forcefully; damaged cables must be replaced by the manufacturer.
  7. Do not drop or impact the motor.
  8. Do not flush the motor with water.
  9. Consult the manufacturer before using a customized product outside the agreed operating conditions.
  10. The motor housing may remain hot after shutdown; use burn-protection measures if necessary.
  11. Ensure no foreign objects have entered the housing during installation.
  12. Rotate the rotor by hand before first startup and confirm there is no collision, interference, or jamming.
  13. The motor is a fan component and must not be operated alone without the impeller or load.
  14. After unpacking, repackage the product for storage in a clean, ventilated, non-corrosive environment at -40°C to +80°C and up to 95% RH, at least 15 cm above ground.
  15. Install the fan out of reach of children.
  16. Blauberg retains final interpretation of this specification.

Life and maintenance, warranty

  1. Design life is 50,000 hours, limited by the ball-bearing life at 40°C; actual life depends on temperature, humidity, installation, and load.
  2. Clean and maintain the fan every 3-6 months according to operating conditions.
  3. The complete fan carries a two-year warranty from the order delivery date for defects caused by product quality; improper disassembly, handling damage, human damage, and force majeure are excluded.

Download

SK-F225E-EC-05 Product Specification.pdf

 

Hot Tags: Blauberg SK-F225E-EC-05 225mm EC Single Inlet Centrifugal Blower, China Blauberg SK-F225E-EC-05 225mm EC Single Inlet Centrifugal Blower manufacturers, suppliers, factory

Send Inquiry
Get in touch
Let's engineer your air solution.

Complete the form and our engineering team will contact you shortly.

bg